Insertion Electromagnetic Flowmeters/Magnetic Flow Meter
Basic Info
Model No.: LZB_3 0.15-1.5
Product Description
Model NO.: LZB_3 0.15-1.5 Main Application: Water, Wastewater, Diesel Fuel, Fuel Oil, Corrosive Liquid/Gas Sensor: Clamp-on/External Type: Electromagnetic flow meter Measuring Principle: Electrical Principles Ex-Proof: Intrinsic Safety/ Explosion-Proof LCD: Yes/No Medium: Liquid, Air, Gas Transport Package: Wooden Case or Carton Origin: Tianjin, China Accuracy: ±0.2-0.5% Size: Dn10~Dn3000 Application: Industrial Production Measuring Media: Gas Certification: JIS, DIN, ANS, GB, CE, UL, RoHS, ISO Pressure: Suitable for Very High Pressure Signal: 4-20mA, Pulse, RS485, Hart Trademark: U-ideal Specification: ANSI JIP DIN JS and others HS Code: 90261000 Product Description
InsertionType Vortex Flow Meter for Gas/Steam/Liquid
1.This series Flowmeter can accurately measure within wide flow range of gas, liquid and steam flow rate but not influenced by fluid physical properties at the same time.
2 It is not affected by temperature and pressure, have the advantages of not easy to block, not easy card. And resistance high temperature and high pressure, safe and explosion-proof. It is used to the bad environment.
3 No moving parts and no hole aperture design. Long service life.
4 Adopting micro power consumption of new and high technology, this batery with display type flowmeter can work more than two years with continuos electricity.
5 Temperature compensation and integrated design
6 Output current type of electrical isolation, Has the good common-mode interference suppression.
7 it is Also showed flow values and cumulative flow value, and don't have to take turns to switch
8 Using vibration probe, the effective elimination of the influence of external vibration.
Packaging & Shipping
Standard export package: each unit has individual box and all boxes are packed in standard packages
As the clients requirement
Contact us if you need more details on Insertion Electromagnetic Flowmeters. We are ready to answer your questions on packaging, logistics, certification or any other aspects about Magnetic Flow Meter、Magnetic Inductive Flow Sensor. If these products fail to match your need, please contact us and we would like to provide relevant information.
InsertionType Vortex Flow Meter for Gas/Steam/Liquid
1.This series Flowmeter can accurately measure within wide flow range of gas, liquid and steam flow rate but not influenced by fluid physical properties at the same time.
2 It is not affected by temperature and pressure, have the advantages of not easy to block, not easy card. And resistance high temperature and high pressure, safe and explosion-proof. It is used to the bad environment.
3 No moving parts and no hole aperture design. Long service life.
4 Adopting micro power consumption of new and high technology, this batery with display type flowmeter can work more than two years with continuos electricity.
5 Temperature compensation and integrated design
6 Output current type of electrical isolation, Has the good common-mode interference suppression.
7 it is Also showed flow values and cumulative flow value, and don't have to take turns to switch
8 Using vibration probe, the effective elimination of the influence of external vibration.
1. Feature | |||||
Available: Liquid, Gas, Steam Not For: liquid with high viscosity Vibration will affect the accuracy No moving part Fluid temperature: +250ºC | |||||
2. Specifications | |||||
Product Structure | |||||
Simple Insertion | Insertion with Ball Valve | ||||
Type | A Type | B Type | |||
Accuracy | ±2.5% | ±2.5% | |||
Display | Optional | Optional | |||
Output Signal | Optional: Pulse or 4-20mA | Optional: Pulse or 4-20mA | |||
Communication | Optional: RS485 | Optional: RS485 | |||
Power Supply | +24VDC±15% | +24VDC±15% | |||
Explosion Proof | Optional: ExdIIBT6 or ExiaIICT4 | Optional: ExdIIBT6 or ExiaIICT4 | |||
Protection Level | IP65 | IP65 | |||
Product Material | 304SS | 304SS | |||
Pressure Rating | 1.0MPa | 1.0MPa | |||
Fluid Temperature | -20ºC~250ºC | -20ºC~250ºC | |||
Ambient Temperature | -20ºC~70ºC | -20ºC~70ºC | |||
3. Flow range | |||||
Diameter (mm) | Flow Range (m3/h) | Diameter (mm) | Flow Range (m3/h) | ||
Liquid | Gas | Liquid | Gas | ||
200 | 70-700 | 600-6000 | 500 | 450-4500 | 4200-42000 |
250 | 110-1100 | 1060-10600 | 600 | 600-6000 | 6100-61000 |
300 | 180-1800 | 1500-15000 | 800 | 800-8000 | 11000-110000 |
Standard export package: each unit has individual box and all boxes are packed in standard packages
As the clients requirement
Contact us if you need more details on Insertion Electromagnetic Flowmeters. We are ready to answer your questions on packaging, logistics, certification or any other aspects about Magnetic Flow Meter、Magnetic Inductive Flow Sensor. If these products fail to match your need, please contact us and we would like to provide relevant information.
Product Categories : flow meter > Electromagnetic Flowmeter
Premium Related Products
Other Products
Hot Products
High pressure natural gas instrument air manifoldStainless steel industrial 3-way valve manifoldFloat angle double block and bleed plug valve3 way lockable forged ball valvestainless steel three way port ball valveThreaded stainless steel cross ball valvesStainless high pressure air precision needle valveTube compression fittings angle air operate needle valvecf8m stainless steel female male automatic ball valve.JW-LOK Hamlet instrument ball valveStainless steel multi port gauge valveHigh pressure 2 way valve manifoldHigh pressure 6000psig bar stock ball valveSpeedy Trunnion Mounted Ball Valve for natural gasMost selling products of radiator auto air vent valveHigh quality Forged steel piston globe valve