YGHB type low voltage control valve
Basic Info
Model No.: Customized
Product Description
The electromagnetic pulse valve (also called diaphragm valve) is the compressed air switch of the dust collecting system of the pulse bag type dust collector. Under the control of the output signal of the pulse injection control instrument, the dust is blown by the filter bag, and the negative force of the dust collector is kept within the set range, so as to ensure the handling capacity and the dust efficiency of the dust collector. The DMF-Z type electromagnetic pulse valve is a right angle valve. The angle between its inlet and outlet is 90 degrees. It is suitable for the installation and connection of the falcons and the spray pipe of the dust collector. The airflow is smooth, which can provide the green gray veins that meet the requirements.
Pulse Solenoid Valve, electromagnetic pulse valve working principle:
The diaphragm divides the electromagnetic pulse valve into two air chambers in the front and back, and when the compressed air is connected through the throttle hole into the rear room, the pressure of the rear air chamber will be the outlet of the diaphragm valve, and the electromagnetic pulse valve is in the "closed" state. The electric signal of the pulse injection control instrument is disappearing, the armature of the electromagnetic pulse valve is reset, the air chamber is closed, the pressure of the rear air chamber is raised and the film is close to the valve outlet, and the electromagnetic pulse valve is in the "closed" state.
Working conditions:
2, in corrosive or explosive environments, corrosion resistance should be preferred according to safety requirements.
3, if the environment space is restricted, please use the multi-function solenoid valve, because it eliminates bypass and three manual valves and is convenient for online maintenance.
4, the power supply voltage fluctuations usually AC +%10%.-15%, DC tolerance of about%10, if ultra poor, must take measures to stabilize or put special order requirements.
5, the highest and minimum temperature of the environment should be selected within the allowable range. If there is excess deviation, special orders should be put forward.
6, the power condition of the electromagnetic pulse valve
7, special occasions such as vibration, bump and impact should be selected in the environment, such as marine solenoid valves.
Contact us if you need more details on Diaphragm Type Low Voltage Pulse Valve. We are ready to answer your questions on packaging, logistics, certification or any other aspects about Diaphragm Controlled Pneumatic Solenoid Valve、DFFY-40S Solenoid Valve AC1V. If these products fail to match your need, please contact us and we would like to provide relevant information.
Pulse Solenoid Valve, electromagnetic pulse valve working principle:
The diaphragm divides the electromagnetic pulse valve into two air chambers in the front and back, and when the compressed air is connected through the throttle hole into the rear room, the pressure of the rear air chamber will be the outlet of the diaphragm valve, and the electromagnetic pulse valve is in the "closed" state. The electric signal of the pulse injection control instrument is disappearing, the armature of the electromagnetic pulse valve is reset, the air chamber is closed, the pressure of the rear air chamber is raised and the film is close to the valve outlet, and the electromagnetic pulse valve is in the "closed" state.
Working conditions:
When the electromagnetic pulse valve is used, the environmental conditions are very important, which is related to the normal and smooth operation of the electromagnetic pulse valve. The environment conditions of the electromagnetic pulse valve:
2, in corrosive or explosive environments, corrosion resistance should be preferred according to safety requirements.
3, if the environment space is restricted, please use the multi-function solenoid valve, because it eliminates bypass and three manual valves and is convenient for online maintenance.
4, the power supply voltage fluctuations usually AC +%10%.-15%, DC tolerance of about%10, if ultra poor, must take measures to stabilize or put special order requirements.
5, the highest and minimum temperature of the environment should be selected within the allowable range. If there is excess deviation, special orders should be put forward.
6, the power condition of the electromagnetic pulse valve
7, special occasions such as vibration, bump and impact should be selected in the environment, such as marine solenoid valves.
Contact us if you need more details on Diaphragm Type Low Voltage Pulse Valve. We are ready to answer your questions on packaging, logistics, certification or any other aspects about Diaphragm Controlled Pneumatic Solenoid Valve、DFFY-40S Solenoid Valve AC1V. If these products fail to match your need, please contact us and we would like to provide relevant information.
Product Categories : Dust Collector Fittings > Electromagnetic Pulse Valve
Hot Products
High pressure natural gas instrument air manifoldStainless steel industrial 3-way valve manifoldFloat angle double block and bleed plug valve3 way lockable forged ball valvestainless steel three way port ball valveThreaded stainless steel cross ball valvesStainless high pressure air precision needle valveTube compression fittings angle air operate needle valvecf8m stainless steel female male automatic ball valve.JW-LOK Hamlet instrument ball valveStainless steel multi port gauge valveHigh pressure 2 way valve manifoldHigh pressure 6000psig bar stock ball valveSpeedy Trunnion Mounted Ball Valve for natural gasMost selling products of radiator auto air vent valveHigh quality Forged steel piston globe valve