Model NO.: Lzm Main Application: Water, Wastewater, Diesel Fuel, Fuel Oil, Nature Gas, Corrosive Liquid/Gas Sensor: Tube/Flange Type: Variable Area flow meter Measuring Principle: Electrical Principles Rangablility: 500:1 LCD: Yes/No Pressure: Suitable for Very High Pressure Specification: sgs HS Code: 90261000 Accuracy: ±0.2-0.5% Size: Dn15~Dn300 Application: Industrial Production Measuring Media: Gas Certification: JIS, DIN, ANS, GB, CE, UL, RoHS, ISO Ex-Proof: Intrinsic Safety/ Explosion-Proof Medium: Liquid, Air, Gas Trademark: Tianjin U-ideal Instrument Origin: Tianjin, China Gas mass flowmeter (Thermal Gas Meter/Switch) / Thermal Mass Flowmeter
Mass flowmeter
Gas Mass Flowmeter (Thermal Gas Meter/Switch)
Performance Features
Measuring range: 0120Nm/s (20, 101.33KPa)
Measuring Accuracy: ± 1%reading ± 0.5% of full scale
Repeatability: 0.2% of full scale
Flow range: Usually 100: 1(depends on range of Calibration Flow)
Diameter Range: 15mm3000mm
Application: Simple or mixed. Gas contains dust, sand, damp and caustic gas.
Environmental temperature: -40+85(no display); -30+70(with display); Humidity less than 90%RH
Medium Temperature Range: -40+100; -40+200; -40+450; -40+510
Sensor Diameter: 32.5
Diameter of Insertion sensor lever19(Standard)1612
Sensor Material: 316 Stainless SteelHastelloy Alloys titanium
Probe Material(Protector): 316 Stainless Steel(Standard)Hastelloy Alloys
Bidirectional Measurement of Medium Flow
Analog output: Flow: 4-20mADC, Temp: 4-20mADC, Max Loading: 1000Ω
Accumulating pulse output
12 section nonlinear correction, 10 inner nonlinear correction
Communication: Serial Port RS232/RS485
Input Power: 24VDC/600mA220VAC/2W110VAC/3W
Alarm: 12 Relays contact closure pins5A/220V5A/30VDCkeyed setting
Current output correction on-line
Large LCD display: Seven Bits Instantaneous Flow, Eight Bits Accumulative Flow and speed
Procession pressure: 1.6Mpa (Max 20MPa)
Installation Method Forms: Insertion (bucklingbucklingball ValveFlange Connection), Pipeline Type (FlangeScrew Connection)
Explosion Proof: Intrinsic safetyFlame Proof
Protective Class: IP65
Pipes on line insertion
Demarcating Equipment
Wind tunnel: Two test sections: 0.8 m*0.8 m*1.5 m1m*1m*2 m
Uniform magnetic field coefficient: Contact us if you need more details on Calorimetric Mass Flowmeter. We are ready to answer your questions on packaging, logistics, certification or any other aspects about Thermal Mass Flowmeter、Thermal Flow Meter. If these products fail to match your need, please contact us and we would like to provide relevant information.
Mass flowmeter
Gas Mass Flowmeter (Thermal Gas Meter/Switch)
Performance Features
Measuring range: 0120Nm/s (20, 101.33KPa)
Measuring Accuracy: ± 1%reading ± 0.5% of full scale
Repeatability: 0.2% of full scale
Flow range: Usually 100: 1(depends on range of Calibration Flow)
Diameter Range: 15mm3000mm
Application: Simple or mixed. Gas contains dust, sand, damp and caustic gas.
Environmental temperature: -40+85(no display); -30+70(with display); Humidity less than 90%RH
Medium Temperature Range: -40+100; -40+200; -40+450; -40+510
Sensor Diameter: 32.5
Diameter of Insertion sensor lever19(Standard)1612
Sensor Material: 316 Stainless SteelHastelloy Alloys titanium
Probe Material(Protector): 316 Stainless Steel(Standard)Hastelloy Alloys
Bidirectional Measurement of Medium Flow
Analog output: Flow: 4-20mADC, Temp: 4-20mADC, Max Loading: 1000Ω
Accumulating pulse output
12 section nonlinear correction, 10 inner nonlinear correction
Communication: Serial Port RS232/RS485
Input Power: 24VDC/600mA220VAC/2W110VAC/3W
Alarm: 12 Relays contact closure pins5A/220V5A/30VDCkeyed setting
Current output correction on-line
Large LCD display: Seven Bits Instantaneous Flow, Eight Bits Accumulative Flow and speed
Procession pressure: 1.6Mpa (Max 20MPa)
Installation Method Forms: Insertion (bucklingbucklingball ValveFlange Connection), Pipeline Type (FlangeScrew Connection)
Explosion Proof: Intrinsic safetyFlame Proof
Protective Class: IP65
Pipes on line insertion
Demarcating Equipment
Wind tunnel: Two test sections: 0.8 m*0.8 m*1.5 m1m*1m*2 m
Uniform magnetic field coefficient: Contact us if you need more details on Calorimetric Mass Flowmeter. We are ready to answer your questions on packaging, logistics, certification or any other aspects about Thermal Mass Flowmeter、Thermal Flow Meter. If these products fail to match your need, please contact us and we would like to provide relevant information.
Product Categories : mass flowmeter
Premium Related Products
Other Products
Hot Products
High pressure natural gas instrument air manifoldStainless steel industrial 3-way valve manifoldFloat angle double block and bleed plug valve3 way lockable forged ball valvestainless steel three way port ball valveThreaded stainless steel cross ball valvesStainless high pressure air precision needle valveTube compression fittings angle air operate needle valvecf8m stainless steel female male automatic ball valve.JW-LOK Hamlet instrument ball valveStainless steel multi port gauge valveHigh pressure 2 way valve manifoldHigh pressure 6000psig bar stock ball valveSpeedy Trunnion Mounted Ball Valve for natural gasMost selling products of radiator auto air vent valveHigh quality Forged steel piston globe valve